adi-insite-ca
ADI a Resideo company
menu
Image of TC-PDUMH15H

Eaton Tripp Lite PDUMH15HVAT 2.4kW Single-Phase Local Metered Automatic Transfer Switch PDU, Two 200-240V C14 Inlets, 10 C13 Outputs, 1U, TAA

PDUMH15HVAT|TC-PDUMH15H

Eaton Tripp Lite PDUMH15HVAT 2.4kW Single-Phase Local Metered Automatic Transfer Switch PDU, Two 200-240V C14 Inlets, 10 C13 Outputs, 1U, TAA

PDUMH15HVAT|TC-PDUMH15H

Se connecter prix revendeur

Devenir client ADI
Image of TC-PDUMH15H
Eaton Tripp Lite

Eaton Tripp Lite PDUMH15HVAT 2.4kW Single-Phase Local Metered Automatic Transfer Switch PDU, Two 200-240V C14 Inlets, 10 C13 Outputs, 1U, TAA

PDUMH15HVAT | TC-PDUMH15H

Veuillez vous connecter pour voir les tarifs, consulter la disponibilité des produits et ajouter des articles à votre panier.

Aperçu
Spécifications
Documents

Aperçu

The PDUMH15HVAT 2–2.4kW Single-Phase 200–240V Local Metered Automatic Transfer Switch / ATS PDU enables redundant power for network devices with non-redundant power supply configurations. Ideal for data centers and server rooms, it mounts in 1U of space in EIA-standard 19" racks and features 10 C13 outlets. Dual 3.6m input cords with IEC-320 C14 plugs connect to separate primary and secondary single-phase power sources in a nominal voltage range from 200–240V. Plug lock inserts prevent cords from accidental disconnection. The PDUMH15HVAT constantly evaluates the power quality of both input sources. Dynamic solid-state (TRIAC) automatic transfer switching allows the PDU to switch to the secondary source within 2–5 milliseconds should the primary source fail or become unstable to ensure your connected equipment operates without interruption. Built-in slot supports the optional WEBCARDLX (sold separate), which turn the PDUMH15HVAT into a switched PDU by allowing remote access to the PDU for power monitoring, configuration, outlet control and notifications via web browser, SSH, telnet or SNMP. Digital ammeter monitors total output current. LEDs display outlet on/off status and input power status on primary and secondary inputs.

Principales caractéristiques

  • 2.4kW Single-Phase Power Capacity
  • Redundant Power for Non-Redundant Devices
  • 1U Rack Mountable for EIA-19" Racks
  • 10 C13 Outlets with Plug Lock Inserts
  • Dual 3.6m IEC-320 C14 Input Cords
  • Automatic Transfer Switching (2-5 ms)
  • Supports Optional SNMPWEBCARD & WEBCARDLX
  • Digital Ammeter for Output Current Monitoring
  • LED Indicators for Power Status
  • Renseignements généraux

    Nom:Eaton Tripp Lite PDUMH15HVAT 2.4kW Single-Phase Local Metered Automatic Transfer Switch PDU, Two 200-240V C14 Inlets, 10 C13 Outputs, 1U, TAA
    Category:Eaton Tripp Lite, Batteries & Power Supplies, Power Management, Power Distribution Units
    UPC Code:037332197900
    Country of Origin:Taiwan, Province of China. Country of origin is subject to change.

    Spécifications

    Documents et ressources sur les produits