adi-insite-ca
ADI a Resideo company
menu
Altronix ACM AL400ULACMR Proprietary Power Supply

Altronix AL400ULACMR Access Power Controller with Power Supply Charger, Fused Relay Outputs, 12/24VDC at 4A, FAI, 115VAC, Red BC400 Enclosure

AL400ULACMR|AX-AL40ULACM

Altronix AL400ULACMR Access Power Controller with Power Supply Charger, Fused Relay Outputs, 12/24VDC at 4A, FAI, 115VAC, Red BC400 Enclosure

AL400ULACMR|AX-AL40ULACM

Sign In for Dealer Pricing

Become an ADI Customer
Altronix ACM AL400ULACMR Proprietary Power Supply
Altronix

Altronix AL400ULACMR Access Power Controller with Power Supply Charger, Fused Relay Outputs, 12/24VDC at 4A, FAI, 115VAC, Red BC400 Enclosure

AL400ULACMR | AX-AL40ULACM

Please sign in to view pricing and availability and to add to cart.

Overview
Specifications
Documents

Product Overview

Introducing the Altronix AL400ULACMR Access Power Controller, a versatile solution for your access control needs. This powerful unit transforms a 115VAC input into eight independently managed outputs, delivering 12VDC or 24VDC with a total continuous supply of 4A at 12VDC or 3A at 24VDC. Designed for compatibility with various access control devices, it supports both Fail-Safe and Fail-Secure modes. The FACP Interface allows for emergency egress and alarm monitoring, ensuring safety and reliability. With its robust design and easy installation, the AL400ULACMR is perfect for enhancing your security system. Don't miss out on this essential component—order yours today!

Main Features

  • Eight (8) independently controlled outputs.
  • Output options: a) Eight (8) Fail-Safe and/or Fail-Secure power outputs b) Eight (8) formin.C" 5A rated relay outputs c) Any combination of the above.
  • Eight (8) auxiliary power outputs (unswitched).
  • Output fuses are rated at 3.5A.
  • Filtered and electronically regulated outputs.
  • Supervision: - AC Fail - Battery Fail and Battery Presence.
  • Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the eight (8) outputs.
  • Alarm output relay indicates that FACP input is triggered
  • Fire Alarm disconnect input options: a) Normally open (NO) or normally closed (NC) dry contact input b) Polarity reversal input from FACP signaling circuit.
  • Built-in charger for sealed lead acid or gel type batteries.
  • General Information

    Name:Altronix AL400ULACMR Access Power Controller with Power Supply Charger, Fused Relay Outputs, 12/24VDC at 4A, FAI, 115VAC, Red BC400 Enclosure
    Category:Altronix, Batteries & Power Supplies, Power Supplies & Boards, Access Power Controllers
    UPC Code:782239939695
    Country of Origin:United States. Country of origin is subject to change.

    Specifications